C9AD026 L Start, Current Program Config Report
|
|
EBAE006 L 1,P1
|
|
06AF02B L 2,P1\X\Test Type=Diff Press Decay-dP c
|
|
91B0034 L 3,P1\X\= a
|
|
4CB1034 L 4,P1\X\=Measures the Pressure Loss (dP), a
|
|
E1B2034 L 5,P1\X\=determined from the differential loss a
|
|
79B3034 L 6,P1\X\=between the test part and the a
|
|
49B4034 L 7,P1\X\=reference volume over the duration of a
|
|
C6B5034 L 8,P1\X\=the test timer. The result is a
|
|
76B6034 L 9,P1\X\=presented in units of delta pressure. a
|
|
29B7021 L 10,P1\R\Tool Ext 1=2.50 sec f
|
|
F8B801D L 11,P1\R\Charge=5.00 sec f
|
|
D6B901B L 12,P1\R\Fill=5.00 sec f
|
|
E8BA021 L 13,P1\R\Stabilize=10.00 sec f
|
|
45BB01F L 14,P1\R\Isolation=50.00 % f
|
|
6CBC01C L 15,P1\R\Test=10.00 sec f
|
|
E3BD01E L 16,P1\R\Exhaust=0.50 sec f
|
|
DDBE021 L 17,P1\R\Tool Ret 1=1.00 sec f
|
|
82BF029 L 18,P1\P\Charge Min Press=0.400 mbar f
|
|
3EC002E L 19,P1\P\Charge Target Press=140.000 mbar f
|
|
77C102C L 20,P1\P\Charge Max Press=6894.757 mbar f
|
|
49C202A L 21,P1\P\Minimum Pressure=95.000 mbar f
|
|
27C302A L 22,P1\P\Target Pressure=100.000 mbar f
|
|
39C402B L 23,P1\P\Maximum Pressure=120.000 mbar f
|
|
E5C502A L 24,P1\P\Target Press Window=100.00 % f
|
|
DBC602A L 25,P1\S\Low Limit Loss=-6894.758 dPa f
|
|
3EC7028 L 26,P1\S\High Limit Loss=90.000 dPa f
|
|
D5C8023 L 27,P1\S\Decay Direction=Loss c
|
|
F8C9024 L 28,P1\S\Test Evaluation=F/P/F c
|
|
74CA023 L 29,P1\S\Loss Offset=0.000 dPa f
|
|
01CB01D L 30,P1\S\EDC Enabled=No c
|
|
72CC021 L 31,P1\S\EDC Percentage=25% c
|
|
26CD01E L 32,P1\S\EDC Quantity=30 i
|
|
4BCE01F L 33,P1\M\Program Name=H R a
|
|
CACF023 L 34,P1\M\Barcode Required=Yes c
|
|
A9D0024 L 35,P1\M\Barcode Method=Unique c
|
|
20D1024 L 36,P1\M\Copy to Target Prog=1 i
|
|
47D201E L 37,P1\M\Copy Program=No c
|
|
4AD3023 L 38,P1\M\Retain Part Press=No c
|
|
11D4026 L 39,P1\M\Malfunction Eval=Reject c
|
|
A1D5030 L 40,P1\M\Pressure Select=Pressure Source 1 c
|
|
79D6023 L 41,P1\M\Leak Std Select=None c
|
|
8BD7022 L 42,P1\M\ERC Method=Disabled c
|
|
63D802A L 43,P1\M\Prefill Method=Fixed Charge c
|
|
52D902A L 44,P1\M\Pressure Correction=Enabled c
|
|
B0DA022 L 45,P1\M\Exhaust Method=Dump c
|
|
49DB024 L 46,P1\A\Autorun Relax=3.00 sec f
|
|
18DC026 L 47,P1\A\Autorun Method=Standard c
|
|
57DD025 L 48,P1\A\Autorun Cycle Count=10 i
|
|
99DE020 L 49,P1\A\Autorun Enable=No c
|
|
58DF01C L 50,P1\U\Time Unit=sec c
|
|
9BE0022 L 51,P1\U\Time Precision=X.XX c
|
|
F9E1021 L 52,P1\U\Pressure Unit=mbar c
|
|
F4E2027 L 53,P1\U\Pressure Precision=X.XXX c
|
|
FFE3022 L 54,P1\U\d Pressure Unit=dPa c
|
|
F2E4026 L 55,P1\U\d Press Precision=X.XXX c
|
|
24E501C L 56,P1\I\I/O ID=786561 a
|
|
99E601E L 57,P1\I\1=Start Channel c
|
|
49E701D L 58,P1\I\2=Part Present c
|
|
1EE801B L 59,P1\I\3=Unassigned c
|
|
66E901B L 60,P1\I\4=Unassigned c
|
|
48EA01B L 61,P1\I\5=Unassigned c
|
|
BEEB01B L 62,P1\I\6=Unassigned c
|
|
ECEC01B L 63,P1\I\7=Unassigned c
|
|
BFED01C L 64,P1\I\8=Constrained c
|
|
A5EE01B L 65,P1\I\9=Unassigned c
|
|
2EEF01C L 66,P1\I\10=Unassigned c
|
|
46F001C L 67,P1\I\11=Unassigned c
|
|
DDF101C L 68,P1\I\12=Unassigned c
|
|
FBF201C L 69,P1\O\I/O ID=786561 a
|
|
D5F301D L 70,P1\O\1=Press Select c
|
|
27F401F L 71,P1\O\2=Program Reject c
|
|
71F501C L 72,P1\O\3=Test Passed c
|
|
1BF601E L 73,P1\O\4=Tool Extend 1 c
|
|
FAF701B L 74,P1\O\5=Unassigned c
|
|
52F801B L 75,P1\O\6=Unassigned c
|
|
08F901C L 76,P1\O\7=Constrained c
|
|
5EFA01F L 77,P1\O\8=Program Reject c
|
|
D6FB01C L 78,P1\O\9=Constrained c
|
|
13FC01D L 79,P1\O\10=Constrained c
|
|
70FD01C L 80,P1\O\11=Unassigned c
|
|
98FE01C L 81,P1\O\12=Unassigned c
|
|
11FF020 L 82,P1\T\Tooling Option=On c
|
|
EF00022 L 83,P1\T\Number of Motions=1 c
|
|
6C01025 L 84,P1\T\Two Inputs to Start=No c
|
|
DE0202C L 85,P1\T\Part Present Check=Test Start c
|
|
E60301E L 86,P1\T\Motion Number=1 c
|
|
5A04024 L 87,P1\T\Retract on Reject=Yes c
|
|
690501D L 88,P1\T\Part Mark=None c
|
|
C306026 L 89,P1\T\Tooling Feedback 1=None c
|
|
8507025 L Stop, Current Program Config Report
|
|
2E08028 V I\S\RS232 1 REPORT=Cur Prog Config c
|